BJJNV - AKZ TIRE GUN PUNCTURE REPAIR;SNAP (SUP DA)

  • MSDS: BJJNV
  • Manufacturer: NATIONWIDE INDUSTRIES CORP
  • Product Name: AKZ TIRE GUN PUNCTURE REPAIR;SNAP (SUP DA)
  • National Stock Number: 2640-00-444-2115
Product Identification

Product ID:AKZ TIRE GUN PUNCTURE REPAIR;SNAP (SUP DA)
MSDS Date:01/26/1990
FSC:2640
NIIN:00-444-2115
MSDS Number: BJJNV

Responsible Party
NATIONWIDE INDUSTRIES CORP
501 S BASINGER RD
PANDORA, OH 45877
US

Emergency Phone: 419-384-3241

Info Phone: 419-384-3241

Preparer: RICHARD W LEHMAN

Cage: 74438

Contractor
NATIONWIDE INDUSTRIES CORP
PANDORA, OH 45877-9749 US

Cage: 74438

Ingredients

METHYL CHLOROFORM (1,1,1-TRICHLOROETHANE) (SARA III)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 40-50%

OSHA PEL 350 PPM

ACGIH TLV: 350 PPM/450STEL;9394

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CHLORODIFLUOROMETHANE

CAS: 75-45-6

RTECS: PA6390000

Fraction By Weight: 45-60%

OSHA PEL 1000 PPM

ACGIH TLV: 1000PPM; 9192

Hazards

LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS AND SYMPTOMS OF
OVEREXPOSURE.
Explanation of Carcinogenicity:CHLORODIFLUOROMETHANE:INADEQUATE
EVIDENCE FOR CARCINOGENICITY IN HUMANS/LIMITED EVID FOR CARCIN IN
ANIMALS (IARC,1987).
Effects of Overexposure:EYES:IRRIT &/OR CORNEAL
INJ.SKIN:IRRIT.ABSORPTION THROUGH SKIN UNLIKELY.INGEST:LOW ORAL
TOXICITY.BEWARE OF CHEMICAL PNEUMONIA.INHAL:MAJOR POTENTIAL ROUTE
OF OVEREXPOSURE.DIZZINESS,DROWSINESS,IRRITATIO N.AT HIGH LEVELS IS
A BLOOD PRESSURE DEPRESSANT,CARDIAC SENSITIZER & VENTRICULAR
ARRHYTHMIA.TARGET ORGANS:LIVER & HEART.
Medical Cond Aggravated by Exposure:N/K

First Aid

First Aid:EYES:FLUSH WITH LARGE QUANTITIES OF WATER.CALL
PHYSICIAN.SKIN:REMOVE CONTAMINATED CLOTHING.WASH WITH SOAP AND
WATER.INGESTION:DO NOT INDUCE VOMITING.DANGER OF CHEMICAL
PNEUMONIA.CALL PHYSICIAN.NOTE:AD RENALIN TYPE DRUGS SHOULD NOT BE
GIVEN TO OVEREXPOSED VICTIM.INHALATION:REMOVE TO FRESH
AIR,ADMINISTER CPR IF NECESSARY.CALL A PHYSICIAN.

Fire Fighting

Flash Point:NONE
Extinguishing Media:WATER FOG,CARBON DIOXIDE.
Fire Fighting Procedures:KEEP CONTAINERS COOL.USE EQUIPMENT OR
SHIELDING TO PROTECT PERSONNEL AGAINST BURSTING,RUPTURING OR
VENTING CONTAINERS.
Unusual Fire/Explosion Hazard:AT ELEVATED TEMP,(>130F,54.44C) CONTR MAY
VENT/RUPTURE/BURST.FLAMM.PROPELLANT HEAVIER THAN AIR & MAY REMAIN
FLAMM UNTIL CONC IS REDUCED BELOW FLAMMABLE LIMITS.

Accidental Release

Spill Release Procedures:IF CONTAINERS ARE LEAKING OR LARGE AMOUNTS ARE
RELEASED,AVOID BREATHING VAPORS & AVOID SKIN CONTACT WITH LIQUID.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:DO NOT STORE WHERE TEMPERATURE COULD
EXCEED 54C,130F.
Other Precautions:READ AND FOLLOW INSTRUCTIONS ON THE PRODUCT LABEL.

Exposure Controls

Respiratory Protection:NOT APPLICABLE IN NORMAL USE.
Ventilation:LOCAL EXHAUST SHOULD BE SUFFICIENT TO REMOVE SOLVENT &
PROPELLANT VAPOR.MECHANICAL (GENERAL) SHOULD BE ON WHEN SPRAYING.
Protective Gloves:NOT APPLICABLE IN NORMAL USE.
Eye Protection:NOT APPLICABLE IN NORMAL USE.
Other Protective Equipment:DO NOT WEAR CLOTHING SOAKED BY SPRAY.
Work Hygienic Practices:DO NOT WEAR CLOTHING SOAKED BY SPRAY.
Supplemental Safety and Health
PART NO:FIX A FLAT S-275.VP:APPROX 165 PSIG @ 54.5C,130F.VAP DENS:>1.0
(AIR=1) @ 15-32C,60-90F.ROUTES OF ENTRY:SKIN/INGESTION .WASTE DISP
METH:LEAKING/FULL CONTR TO DISP SERVICE EQUIPPED TO SAFE LY HANDLE
& DISPOSE OF PRESSURIZED CONTAINERS.

Chemical Properties

Boiling Pt:B.P. Text:N/K
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Pres:SEE SUPP
Vapor Density:SEE SUPP
Evaporation Rate & Reference:>1.0 (N-BUTYL ACETATE=1)
Solubility in Water:TRACE
Appearance and Odor:NO DISTINGUISHING PATTERN AND CHLORINATED ODOR.
Percent Volatiles by Volume:95+

Stability

Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS.
Stability Condition to Avoid:N/K
Hazardous Decomposition Products:CARBON MONOXIDE,PHOSGENE,HYDROFLUORIC
ACID,HYDROCHLORIC ACID.

Disposal

Waste Disposal Methods:DISP MUST BE IN ACCORDANCE WITH FED,STATE &
LOCAL REGS.COORDINATION W/ SUPPORTING INSTALLATION &/OR MACOM
ENVIRONMENTAL COORDINATION PRIOR TO DISP IS RECOMND TO DETERMINE
APPROP DISP METH .DO NO T PUNCTURE/INCIN CONTR.GIVE EMPTY/ (SEESUPP
DATA)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.